5 research outputs found

    JPEG compression of monochrome 2D-barcode images using DCT coefficient distributions

    Get PDF
    Two dimensional (2D) barcodes are becoming a pervasive interface for mobile devices, such as camera phones. Often, only monochrome 2D-barcodes are used due to their robustness in an uncontrolled operating environment of camera phones. Most camera phones capture and store such 2D-barcode images in the baseline JPEG format. As a lossy compression technique, JPEG does introduce a fair amount of error in the decoding of captured 2D-barcode images. In this paper, we introduce an improved JPEG compression scheme for such barcode images. By altering the JPEG compression parameters based on the DCT coefficient distribution of such barcode images, the improved compression scheme produces JPEG images with higher PSNR value as compared to the baseline implementation. We have also applied our improved scheme to a real 2D-barcode system - the QR Code and analyzed its performance against the baseline JPEG scheme

    A reverse transcription loop-mediated isothermal amplification for broad coverage detection of Asian and African Zika virus lineages.

    Get PDF
    BACKGROUND: Early detection of Zika virus (ZIKV) infection during the viremia and viruria facilitates proper patient management and mosquito control measurement to prevent disease spread. Therefore, a cost-effective nucleic acid detection method for the diagnosis of ZIKV infection, especially in resource-deficient settings, is highly required. METHODS: In the present study, a single-tube reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay was developed for the detection of both the Asian and African-lineage ZIKV. The detection limit, strain coverage and cross-reactivity of the ZIKV RT-LAMP assay was evaluated. The sensitivity and specificity of the RT-LAMP were also evaluated using a total of 24 simulated clinical samples. The ZIKV quantitative reverse transcription-polymerase chain reaction (qRT-PCR) assay was used as the reference assay. RESULTS: The detection limit of the RT-LAMP assay was 3.73 ZIKV RNA copies (probit analysis, P ≤ 0.05). The RT-LAMP assay detected the ZIKV genomes of both the Asian and African lineages without cross-reacting with other arthropod-borne viruses. The sensitivity and specificity of the RT-LAMP assay were 90% (95% CI = 59.6-98.2) and 100% (95% CI = 78.5-100.0), respectively. The RT-LAMP assay detected ZIKV genome in 9 of 24 (37.5%) of the simulated clinical samples compared to 10 of 24 (41.7%) by qRT-PCR assay with a high level of concordance (κ = 0.913, P < 0.001). CONCLUSION: The RT-LAMP assay is applicable for the broad coverage detection of both the Asian and African ZIKV strains in resource-deficient settings

    Click and mortar of retail banking : a case study in Hong Kong.

    No full text
    This report explores how banks in Hong Kong have changed their ways in the conduct of retail banking businesses with the implementation of Internet banking, and how these changes have affected the bricks-and-mortar distribution channels of banks.Master of Business Administration (Marketing
    corecore